Skip to Content
Teleoperating the armTroubleshooting

Troubleshooting

Every entry here is a real failure from bringing the Quest up on the Jetson. Most share a shape: the reader looks broken and the cause is in the headset. Two commands answer most questions before you touch any Python:

adb shell dumpsys OVRRemoteService | grep -o "ExternalStatus: [A-Z_]*, TrackingStatus: [A-Z_]*" adb logcat -d -s wE9ryARX | tail -1

The first is the headset’s own view of the controller. The second is the raw line the reader parses: the right controller’s 4x4 transform and its buttons.

The buttons work but the pose never changes

/quest/joy shows the grip and trigger, /quest/right/pose sits at one value within a millimetre, and the raw logcat line shows the left and right controllers with the identical transform near the origin.

The headset put the controller to sleep. dumpsys OVRRemoteService says CONNECTED_INACTIVE, and the system log has

ControllerManagement: Controller ... sent to sleep as hand tracking is enabled and controllers are not in use

Buttons ride over Bluetooth and keep working; position needs the controller awake and in view of the headset’s cameras. Turn off Auto switch from controllers to hands in the headset’s Movement tracking settings (see Setting up the Quest), then pick the controller up. It takes about ten seconds from pickup to full tracking.

device unauthorized, on every start

The reader exits with

Device is visible but could not be accessed.

and adb devices inside the container says unauthorized. The headset was authorized with a one-time Allow, so each new adb server needs a fresh prompt. Accept the dialog again with Always allow from this computer ticked, and make sure the quest3 alternative mounts /home/abra/.android, or the key that was authorized is thrown away with the container.

If the prompt never appears, the headset is asleep or unworn; a Quest cannot show the dialog to nobody. Put it on.

Device not found right after the container starts

Starting a privileged container with /dev mounted resets the headset’s USB link. For a second or two lsusb still lists the Quest but adb has nothing. The reader waits up to 15 s for this, so seeing it means the wait ran out. Check the cable carries data (some USB-C cables are charge-only) and that no other adb server on the host has the device claimed. Two adb servers cannot share one USB device.

The headset is on but not in the USB list

A Quest with a flat battery shows a charge light and nothing on USB until Android boots, and a Jetson port charges it slowly. Charge it on a wall brick until it reaches the home screen, then move the cable.

stream closed by driver a quarter second after stream open

The driver expires a stream that receives no setpoint for stream_timeout_s (0.2 s). Versions before 0.1.0 published nothing until the first controller pose arrived, which on a slow adb connect was later than that. The node now publishes a hold target from the first tick. If you see this on a current image, the setpoints are not reaching the driver: check both containers share --network host, --ipc host and the same ROS_DOMAIN_ID.

ros2 topic echo prints nothing and everything is fine

/setpoint/*, /ee_state and /joint_states are best-effort; /stream_status and /control_status are reliable and latched. The default ros2 topic echo matches neither.

ros2 topic echo --qos-reliability best_effort /setpoint/pose ros2 topic echo --once --qos-durability transient_local /stream_status

Inside a module container, ros2 topic commands can also hit a wedged ROS 2 daemon and fail with !rclpy.ok(). Add --no-daemon.

The pose is stale and the reader says nothing

The headset app died. From ROS it is indistinguishable from a resting controller: oculus_reader returns the last pose it parsed, forever. The reader’s watchdog relaunches the app within 2 s and logs

[quest_reader]: headset app was dead, relaunched it (#1)

If the relaunches repeat, adb logcat on the headset will say why the app exits. To relaunch by hand:

adb shell am start -n com.rail.oculus.teleop/.MainActivity

The arm veers, or forward is sideways

R_align is wrong or stale. It is tied to the headset’s boot-time frame, so a headset reboot invalidates it silently. Hold A for two seconds and make the forward gesture again (Calibrate after every headset reboot). A mirrored axis means the gesture pointed the wrong way; a small consistent veer means it drifted sideways.

The arm driver died with WRONG_SERVOING_MODE

terminate called after throwing an instance of 'Kinova::Api::KDetailedException' what(): Device error, Error sub type=WRONG_SERVOING_MODE

That is kinova-gen3-ros2 1.0.1 crashing on a servoing-mode switch, which a stream open or close triggers. It is not something the teleop node can prevent; restart the driver (sheppy woof arm) and report it against the driver with the log. The teleop node sees the stream drop and freezes; the arm goes limp rather than moving.

Two teleop nodes, and the arm keeps stopping

The driver’s /acquire_control seizes, so a second node halts the first, and each open replaces the other’s stream. Run one alternative. See Two things that surprise people.